Another part of the basement we have a vinyl floor product that interlocks without grout not sure if it was glued with no issues.
Carpet over concrete moisture.
Over time hydrostatic pressure will force that moisture upwards and can cause bubbles in surface treatments and cracks in covering materials that are installed above it.
The solution which you already alluded to would be to install 3 4 1 of eps over the slab held down with a subfloor tapconned to the slab.
Carpeting over concrete floors can be a quick affordable and smart way to warm up a cool room reduce noise in your workplace and turn a bland and uninspiring space into somewhere warm and inviting.
If excess moisture is present in a concrete slab when an impermeable surface treatment is installed it will become trapped under that covering.
Plywood carpet pad and carpet as shown.
Seal the floor either chemically or via membranes this creates an impermeable barrier between the sub floor and your flooring which means moisture cannot penetrate into your flooring.
However moisture levels can and do fluctuate over time so your sub floor moisture measurements may give you a false sense of security.
Installing carpet over a basement concrete cement floor can be a simple project and requires very few tools to accomplish.
When checking concrete moisture the best solution to get readings of moisture deep in the slab is to use the astm f 2170 standard.
1 to prevent moisture migration up through concrete substrates located on and below grade and damage to installed floor coverings the concrete slab shall be protected from ground moisture and hydrostatic pressure by the use of an industry approved vapour retarder moisture barrier or waterproof membrane having a permeance of less than 0 3 perms 0 2 metric perms in accordance with astm e 96.
This standard calls for the use of a thermo hygrometer with in situ probes to measure the.
Concrete absorbs and retains water and the moisture can seep into the carpet padding and then into the carpet.
And both of the options use the same layers of 1 2 in.
With an insulating carpet above the slab the slab temperature can be low enough to create a mold problem at the deeper levels of the carpet.
For below grade slabs assume that the concrete floor will get damp at some point.
Choosing the right carpet.
This task can be simple but it does require planning patience and the right tools.
Any kind of persistent moisture will allow mold to get a foothold and soon ruin carpet or wood flooring.
You then have two options depending on your circumstances.
The floor outside the bathroom walls is either carpet or bare concrete neither have moisture.